We would like to use Google Analytics to be able to monitor how our site performs and how it is used.This requires a few cookies to be set on your device. If you're OK with that, please just continue as normal.If you'd prefer that we didn't, please just turn cookies off using the button below. The Privacy Policy has more information. We'll also be setting a few essential functional cookies to enable the cart, language and currency settings - these are not affected by this setting.

By using our site you accept the terms of our Privacy Policy.

(One cookie will be set to store your preference)
(Ticking this sets a cookie to hide this popup if you then hit close. This will not store any personal information)

About this tool

About Cookie Control
Measurably better value

🛒 Empty

tooltip icon

Resource Details

File/link type icon for HEX

LD400P firmware files V1.11/V1.06



Updates to the device firmware may be made available from time to time.  This firmware resides in flash memory and can be updated via the USB interface.  The firmware versions can be checked using the *IDN? query from the remote interface. 

The LD400P uses two firmware files; one for the main hardware and one for the interface board.  This version is a complete firmware update with main firmware V1.09 and interface firmware V1.06.

  • Version 1.04/1.05 fixed a bug for voltages over 65V when read over the automation interfaces.
  • Interface firmware V1.05 included LXI/LAN code updates to fix mDNS related network dropout issues.
  • Main firmware V1.05 was never released.
  • Main firmware V1.06 is a preventative measure that fixes theoretically possible issues with calibration checksums.
  • Interface Firmware V1.06 fixes intermittent LAN dropout issues
  • Main firmware V1.07 introduces a battery test feature - this is documented in Issue 5 of the operation manual
  • Main firmware versions 1.08 to 1.11 were required for manufacturing processes and the only change visible to the end user is an additional message on trip which says "Check Voltage Sense Switch".  This is to reduce the chance of a non-faulty unit being returned because of remote sense being enabled but disconnected.