CPX DC Supplies: Variable OVP and OCP trips
Over-voltage trip
When in manual operation mode, the CPX Series has an OVP control
that is set from the front panel (individually set per output on
dual output models).
In bus controlled mode (CPX200DP, CPX400SP and CPX400DP only),
this is replaced by a bus programmable OVP protection that can be set in 0.1V increments
Over-current trip
The over-current trip is available only on
the CPX200DP, CPX400SP and CPX400DP models and is only active when in
bus controlled mode. OCP can be set in increments of 10mA.