PSA Series Tour Map
PSA Series 5 hand-held RF spectrum analyzers: Logging
Logging of data, traces and screens
The logging function* enables information from the
sweep to be captured within log files. The
information recorded can be the centre level, the peak level found in
the sweep, the whole trace, or the whole screen image.
Up to 25,000 entries can be stored per file. The large internal
disk (1.8GB) provides enormous log file capacity.
Entries can be made every sweep (continuous)
manually (key press), at timed intervals (from seconds to hours), or in
response to an external trigger signal or the internal limits
comparator.
Entries are time stamped from the
real-time clock, and each log file includes a header describing the
set-up of the instrument.
Log file analysis is done
on a PC using PSA-Manager software.